1,5 mtr Solar aansluitkabel M+F MC4-MC4 Zwart 6mm2
Article numéro:
PV.AKZ.MM.MF.0150.6
8,88 €
8,43 €
Excl. Tax
(
10,20 €
Incl. Taxe
)
Excl. Tax
(
Incl. Taxe
)
(
Incl. Taxe
)
La description
1,5 mtr Solar aansluitkabel M+F MC4-MC4 Zwart 6mm2
Plus d'information
SKU
- PV.AKZ.MM.MF.0150.6
GTIN
- 08718819221913
Conductor material
- Copper
Conductor surface
- Tinned
Nominal cross section conductor
- 6 mm²
AWG size
- 10
Conductor category
- Class 5 = flexible
Conductor resistance at 20 °C
- 3.39 Ohm/km
Shape of conductor
- Round
Number of cores
- 1
Material core insulation
- Other
Protective conductor
- No
Specification core insulation
- Other
Core identification according to HD 308 S2
- No
Core identification
- Colour
Laminated sheath
- No
Fibre optic elements
- No
With protective conductor
- No
Inner semi-conducting layer
- No
Outer semi-conducting layer
- No
Screen
- No
Drain wire
- No
Nominal cross section pilot/reduced conductor
- 0 mm²
Lead sheath
- No
Armouring
- No
Radial water blocking cable
- No
Number of pilot/reduced conductors
- 0
Concentric conductor
- None
Nominal cross section concentric conductor
- 0 mm²
Material outer sheath
- Other
Specification material outer sheath
- Other
Colour outer sheath
- Black
Cable geometry
- Round
Conductive coating
- No
Longitudinal water blocking conductors
- Yes
Longitudinal water blocking screen
- Yes
Flame retardant according to IEC 60332-1-2
- No
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
- No
Flame retardant according to IEC 60332-3-22 (Cat A)
- No
Halogen free according to EN 60754-1/2
- Yes
Flame retardant according to IEC 60332-3-23 (Cat B)
- No
Flame retardant according to IEC 60332-3-24 (Cat C)
- No
Flame retardant
- According to IEC/EN 60332-1-2
Low smoke (according to EN 61034-2)
- Yes
Flame retardant according to IEC 60332-3-25 (Cat D)
- No
Low smoke according to EN IEC 61034-2
- Yes
Halogen free according to EN IEC 60754-1
- No
Halogen free according to EN IEC 60754-2
- Yes
Insulation integrity according to IEC 60331
- Yes
Halogen free according to EN IEC 60754-3
- No
Reaction-to-fire according to EN 13501-6: Class
- Dca
Insulation integrity
- None
Circuit integrity
- None
Reaction-to-fire according to EN 13501-6: Smoke production
- s2
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
- d2
Oil resistant (according to IEC 60811-404)
- Yes
Reaction-to-fire according to EN 13501-6: Acidity
- a3
Circuit integrity according to EN 50200 annex E
- No
Oil resistant according to EN IEC 60811-404
- No
Min. permitted bending radius, stationary application/permanent installation
- 30 mm
Weight
- 100 kg/km
Max. conductor temperature
- 120 °C
Permitted cable outer temperature during assembling/handling
- -40 - 90 °C
Permitted cable outer temperature after assembling without vibration
- -40 - 90 °C
Nominal voltage U0
- 1 kV
Nominal voltage U
- 1.5 kV
Nominal equivalent cross section of reinforcement
- 0 mm²
Circuit integrity according to EN 50200 annex E
- No
UV resistant
- No
Suitable for underground installation
- No
Suitable as installation cable
- Yes
Certified for shipboard application
- No
Suitable as medium-voltage cable
- No
Circuit integrity according to IEC 60331-21
- No
Suitable as high-voltage cable
- No
Certified as airport lighting cable
- No
Flame retardant according to EN 60332-1-2
- No
Flame retardant according to EN 60332-3-21 (Cat A F/R)
- No
With rodent protection
- No
Flame retardant according to EN 60332-3-22 (Cat A)
- No
Flame retardant according to EN 60332-3-23 (Cat B)
- No
Flame retardant according to EN 60332-3-24 (Cat C)
- No
Circuit integrity according to BS 6387 CWZ
- No
Circuit integrity according to BS 8434-2
- No
Flame retardant according to EN 60332-3-25 (Cat D)
- No
Halogen free according to EN 60754-1
- No
Halogen free according to EN 60754-2
- No
Halogen free according to EN 60754-3
- No
Nominal cross section conductor (AWG)
- 10 kcmil
Outer diameter approx.
- 6.2 mm